Autotransformers and one-phase LV and MV transformers
Characteristics :
Power: 1 VA up to 20 kVA (depending on the frequency of use)
Frequencies: 50 to 1 kHz
Voltages: 1 V to 10 kV
Fields of use :
- Transmission of electricity from a one-phase network;
- Measure of an electrical parameter (current, voltage);
- Obtaining a quality-price ratio;
- Obtaining a simple and effective industrial profile;
- Obtaining an easily convertible product.
Applications :
- Distribution cabinet from a one-phase network, with or without galvanic isolation;
- Independent transformation post, covered or not, according to a IP00, IP21, IP23, IP54, IP55 or IP65;
- Voltage stabilizer of ±1 or 2% from a highly variable network in amplitude (± 20%) ;
- Ferroresonant;
- Transformation post conditions comparable to ATEX ;
- Extension of very low voltage, high current energy.
These values are given as an example and are not exhaustive for particular solutions
- Our recent productions in this range
Power filter inductance
-
Type of equipment :
Power filter inductance
Value of self: 1.5mH
Current: 240AC
Reactive power: 30000VAR
Frequency: 50 / 60Hz
Electrical class: I
Naked version (IP00)Uses :
Permet de lisser ou de filtrerComments :
Compact and sized according to the electrical and mechanical characteristics that have been entrusted to us.Dimensions (L x H x P) :
Example : 320x380x210mmWeight : 39 Kg
Power filter inductance C. I. mounting
-
Type of equipment :
Balanced filter inductor
Value of self : 10A < < 0.1A
Frequency : 250KHz < <3KHz
Safety class : I
Uncovered version (IP00)Uses :
Smoothes, filter, coordinate, make symmetric, etc.Comments : Compact and dimensioned according to the electrical and mechanical characteristics that have been entrusted to us. Connects to a circuit board.
Dimensions (L x H x P) :
Example : 320x380x210mmWeight : 39 Kg
Power box
-
Type of equipment :
Adjustable and temporisable source of energy
Input : 230 V AC
Output: 360 V AC
Power : 600 VA
Frequency : 50/60 Hz
Safety class : I
Encapsulated (IP65)Uses :
Transportable source of energy on construction site or agricultural site to supply during an adjustable time by the user a compatible electrical energy with its need (heating of resistance, cooking...).Comments :
Taken out by standard or specific cable (with detachable and clipping connector) or by typical index card HYPRA, MARTIN LUNEL, MARSHAL...Dimensions (W x H x D) : According to the power
Example : 310 x 350 x 220mmWeight : 25 Kg
Transformer of ionization
-
Type of equipment :
Single-phase LV / MV power transformer
Input : 230V AC
Output: 12000 V AC
Power : 1800 VA
Frequency : 50/60 Hz
Safety class : I
Nude version (IP00)Uses :
Creation of an electric field of ionization.Comments :
Taken out on an insulating border.Dimensions (W x H x D) : According to the power
Example : 260 x 280 x 180mmWeight : 30 Kg
Armored compact transformer
-
Type of equipment :
Autotransformers and one-phase LV and MV transformers.One phase transformer with insulation, with high mechanical protection, encapsulated to withstand mechanical impact, with earth terminals.
Input : 230 V AC
Output: 230 V AC
Power : 500 VA
Frequency : 50/60 Hz
Safety class : I
Encapsulated (IP20)Uses :
Comments :
Higher than 4000 V galvanic isolation
Small costDimensions (W x H x D) : 180 x 130 x 140 mm.
Weight : 8 Kg.